Carrier Access Adit 600

Adit 600 Broadband Customer Service Terminal which fulfills many channel bank, multiport CSU/DSU, Integrated Access Device, distributed DLC and Digital Cross-connect applications. Supports up to 18 T1s or E1s, 48 voice channels, 40 ISDN BRI ports, 12 V.35 ports, 24 All-Rate OCU-DP ports. Integrated SNMP and GUI management software. The most versatile small access platform available.

horizontal rule

Carrier Access Adit 600
Integrated Access Device T1 Networks

 

horizontal rule

Carrier Access Adit 600 

Scalable, Modular Integrated Access Device for T1 Networks

The AditTM 600 Customer Service Terminal is the ideal solution for delivering broadband voice and data services to small- and medium-sized businesses. It lets local and interexchange carriers and wireless service providers offer their customers a wide variety of bundled voice and data services including business lines (for phones, modems, and fax machines); PBX trunks for phone systems; IP routing and high-speed data lines for computer networks, Internet, e-commerce, video on demand, multimedia applications; as well as 1/0 DCS capabilities for cell sites. The Adit 600 defines a new class of equipment that combines multi-network access, multimedia transport, and multi-service delivery into one platform. The result is an extremely cost-effective, compact and flexible solution that enables service providers to deliver business voice, Internet access, high-speed data, and private line services using the most economical broadband access available today.

Its modular design and architecture allows seamless migration to new technologies and applications so service providers can address future access needs confidently and completely. As they become available, newer service modules are made available through new service interface cards and software updates. In this way, the Adit 600 will support emerging technologies such as IP telephony and softswitching — leveraging the installed base of Adit 600s without substantial additional capital investment. Deploying it now also ensures service providers will no longer have to discard existing access devices to accommodate future network requirements.

Traditional business voice services, including POTS, DID, CLASSSM, and Centrex are supported in the basic Adit 600 platform. Other services can be easily added — with little time, effort or cost — by provisioning different service cards.

An international version is also available.

Features

Scalable bandwidth and capacity
1 to 18 T1s
The ideal solution for meeting the demands of businesses, the Adit 600 can meet growing service and bandwidth requirements by allowing providers to incrementally increase bandwidth by connecting additional T1 lines. It has the capacity to connect up to 18 T1s. The Adit 600 has full network access drop-and-insert capabilities with an integrated 1/0 cross-connect matrix to provide full non-blocking connectivity between any of the six service card slots. This allows any of the 18 T1s to be provisioned as network interface trunks or drop-and-insert fractional T1 tributaries.

Unmatched business-centric service density
Six service card slots provide up to 48 voice lines or any mix of voice and high-speed data services
The Adit 600 provides expansive network and service capacity within an incredibly small unit. With six slots for service cards, it can provide connections for a broad combination of voice and data services. This enables deployment of up to 48 phone lines per chassis or up to 96 lines in two rack units.

A variety of services and cards are available for the Adit 600. For a complete listing, please refer to the Spec Sheets and Guides section on the right-hand side of this page.

Simple installation
Up and running in just 15 minutes with minimal training
A compact unit designed for simplified wall or rack mounting, the Adit 600 can be installed in as little as 15 minutes — on the customer site, at the service provider’s central office or point of presence in the phone network, with minimal training, enabling carriers to substantially reduce installation and training costs. In addition, it can be powered by 110 VAC or –48 VDC with its standard power supply (featuring an integrated battery charger) or from the Adit +24 VDC Power Supply. The Speedway™ optional mounting assembly is available to simplify and speed the deployment of the Adit 600 in wiring closets and other similar locations.

Remote end-to-end management
All the way up to the service demarcation point at customer site
NetworkValet™ EMS enables service providers to reduce service and maintenance costs by remotely configuring, monitoring and testing the Adit 600 from anywhere on the network. Remote operators can make instantaneous service changes, check the operation of the equipment, and often fix problems without having to send a service technician to the customer’s site. This remote end-to-end management enables the operator to control and test the equipment right up to the service demarcation point.

Always-on availability
Fail-safe design; carrier-quality service; UL 1950 and NEBS certified
The Adit 600 is designed to be the most dependable product in its class. In addition to meeting exceptionally high design standards, it is manufactured in a world-class ISO 9001 facility where it meets the highest quality standards. It features a built-in battery charger so that an external rechargeable battery pack can easily be connected to provide up to eight hours of back-up protection in the event of a power failure.

Item Part Number Description

Configured T1 Systems

Adit 600 Base 115/-48V 02-AA1-000000-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates

Adit 600 Base +24V 02-AA2-000000-00 +24V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates

8 FXS Ports 02-AA1-A00000-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates, (1) 8-port FXS card 16 FXS Ports 02-AA1-AA0000-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates, (2) 8-port FXS cards

24 FXS Ports 02-AA1-AAA000-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates, (3) 8-port FXS cards

32 FXS Ports 02-AA1-AAAA00-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates, (4) 8-port FXS cards

40 FXS Ports 02-AA1-AAAAA0-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplates, (5) 8-port FXS cards

48 FXS Ports 02-AA1-AAAAAA-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (6) 8-port FXS cards

Adit 600 Base and 2 V.35 Ports 02-AA1-00000C-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates, and (1) 2-port V.35 Card

8 FXS and 2 V.35 Ports 02-AA1-A0000C-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates, (1) 8-port FXS card, (1) 2-port V.35 card 

16 FXS and 2 V.35 Ports 02-AA1-AA000C-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates, (2) 8-port FXS cards, (1) 2-port V.35 card 

24 FXS and 2 V.35 Ports 02-AA1-AAA00C-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates, (3) 8-port FXS cards, (1) 2-port V.35 card

16 FXS and Quad T-1 Card 02-AA1-AA000E-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates, (2) 8-port FXS cards and (1) Quad T1 Card

Adit 600 Base with Router 02-AA1-00000H-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card faceplates, and (1) Router Card

8 FXS Ports and Router 02-AA1-A0000H-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 4 blank card faceplates, (1) 8-port FXS cards and (1) Router Card

16 FXS Ports and Router 02-AA1-AA000H-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 3 blank card faceplates, (2) 8-port FXS cards and (1) Router Card

24 FXS Ports and Router 02-AA1-AAA00H-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 2 blank card faceplates, (3) 8-port FXS cards and (1) Router Card

32 FXS Ports and Router 02-AA1-AAAA0H-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, 1 blank card faceplates, (4) 8-port FXS cards and (1) Router Card

40 FXS Ports and Router 02-AA1-AAAAAH-00 115/-48V Chassis with power supply, Dual T1 TDM controller, SNMP & RPM management, (5) 8-port FXS cards and (1) Router Card

40 ISDN-BRI Ports 02-AA1-EDDDDD-00 115/-48V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, (5) Octal ISDN-BRI, 1 Quad T1

Configured E1 Systems

Adit 600 E1 Base 115/-48V 02-CA1-000000-00 115/-48V Chassis, power supply, Dual E1 TDM controller, SNMP & RPM management, 5 blank card faceplates

6 E1 Ports and Router 02-CA1-LH0000-00 115/-48V Chassis, power supply, Dual E1 TDM controller, SNMP & RPM management, 4 blank card faceplates, (1) Quad E1 Card and (1) Router Card

Components

115/-48V Chassis 02-000-000000-00 Empty 115/-48V Enclosure with backplane and 5 blank card faceplates.

115/-48V Power Supply Card 730-0040 115VAC/-48VDC power supply / battery charger w/ AC cord for 115/-48V Adit 600 Base P/No. 02-AA1-000000-00 and 115/-48V Chassis P/No. 02-000-000000-00 

+24VDC Power Supply Card 740-0064 +24VDC Power Supply Card for +24V Adit 600 Base P/No. 02-AA2-000000-01

230V Power Supply 740-0082 230V Power Supply

Dual T1 TDM Controller Card 740-0039 One controller card required per system or chassis. Includes SNMP & RPM management features. Note: Minimum controller software release required is Rev.1.2.2

Dual E1 TDM Controller Card 740-0071 One controller card required per system or chassis. Includes SNMP & RPM management features. Note: Minimum E1 controller software release required is Rev.3.2.0

CMG Router Card 740-0070 CMG Router Card

Quad Terminal Server Router Card 740-0079 Quad Terminal Server Router Card, Note: Minimum controller software release required  is Rev. 4.1

Octal P-phone Card 740-0088 8-channel P-phone card for Nortel Electronic Business Set (EBS) applications. Note: Minimum controller software release required is Rev. 6.0.

FXS-8 Card 740-0036 8 channel expansion or replacement card for FXS or E&M conversion interface applications. Note: Obsolete Part - Superceded by 740-0063

FXS-8 Card 740-0063 8 channel expansion or replacement card for FXS or E&M conversion interface applications. Note: Minimum controller software release required is Rev. 1.5

FXO-8 Card 740-0037 8 channel expansion or replacement card for FXO or DPT interface applications Note: Minimum controller software release required is Rev. 1.2.2

Quad T1 Card 740-0044 Four channel T1 card for voice and data applications. Note: Minimum controller software release required is Rev. 1.3.1

Quad E1 Card 740-0072 Four channel E1 card for voice and data applications. Note: Minimum controller software release required is Rev. 3.2.0

Dual V.35 Card 740-0038 Two-channel V.35 data card for connecting a router or other data equipment. Requires one V.35 cable (listed below) per port.

Dual V.35 Card with V.54 Test Capability 740-0065 Two-channel V.35 data card with V.54 loopback and BERT Test Capability. Note: Minimum controller software release required is Rev. 3.0.1

Dual ISDN BRI Card 740-0041 Two-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release required is Rev. 1.2.2

Quad ISDN BRI Card 740-0048 Four-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release required is Rev. 1.2.2

Octal ISDN BRI Card 740-0042 Eight-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release required is Rev. 1.2.2 

10/100 Base-TX Router Card 740-0047 Single port router supporting IP/IPX routing and layer 2 bridging. Note: Minimum controller software release required is Rev. 1.4.1

Single Port OCU-DP Card 740-0066 Single port all rate OCU-DP Card for DDS Service delivery applications. Note: Minimum controller software release required is Rev. 3.2.0

Quad Port OCU-DP Card 740-0067 Quad port all rate OCU-DP Card for DDS Service delivery applications. Note: Minimum controller software release required is Rev. 3.2.0

Blank Faceplates 710-0011 Blank faceplates for empty service card slots.

Adit 600 Accessories

19" and 23" NEBS CO Rack Installation Kit 710-0019 NEBS certified 19" and 23" rack mount solution for mounting two Adit 600 chassis sideby- side. Allows 4 RU (7") rack spacing per Adit 600 rack assembly.

19" and 23" Rack Installation Kit 710-0016 19" and 23" rack mount brackets for mounting two Adit 600 chassis side-by-side, 6-pin mating alarm connector and ground lug. Allows 6 RU (10.5") rack spacing per Adit 600 assembly.

Two-conductor DC power connectors (5 ea.) 790-0004 Mates with -48 DC power connector on rear of Adit 600.

Single Rack Installation Kit connectors & mounting hardware 790-0006 Contains ground lug, mating DC power and alarm connectors, mounting hardware.

One DC power connector, one grounding lug 790-0008 Mates with -48 DC power connector and ground studs on rear of Adit 600.

Serial Console Cable - 12 ft. 005-0064 12 ft. serial console cable with a DB-9 female and DB-9 male

Dual T1 TDM Operating System Update 750-0027 CD ROM for TFTP-loaded field update. Includes SNMP and RPM management.

Manual (CD-ROM) 770-0008 CD ROM version of Adit 600 manual. Included with each Adit 600 system.

Manual (Hard Copy) 770-0009 Paper version of the Adit 600 manual.

Speedway optional 2nd Battery Shel 710-0025 Optional 2nd battery mounting shelf for Speedway wall mount configurations. (Note: Battery Unit P/N 730-0114 must be ordered seperately)

Speedway dual battery cable 005-0091 Dual battery cable, used when using Speedway Installation Kit and 2nd Battery

Speedway Installation Kit 710-0024 Wall Mount Kit with Swing away brackets for mounting single Adit 600 and power backup battery. (Note: Battery Unit P/N 730-0114 must be ordered seperately)

Universal Accessories

Null Modem Adapter 005-0002 25-pin male/25-pin male

DB-9 to DB-25 Female Adapter 005-0007 DB-9 to DB-25 female adapter

V.35 Data Cable - 10 ft.

male V.35/male Winchester 005-0008 10 ft. V.35 Data Cable - male V.35 / male Winchester

V.35 Data Cable - 10 ft.

male V.35/female Winchester 005-0014 10 ft. V.35 Data Cable - male V.35 / female Winchester

Installation Connector Kit 790-0011 One 66 block, one T-1 cable, one 10' Amphenol cable

Battery Unit 730-0114 Battery unit for use with Adit 600.

V.35 Data Cable - 25 ft.

male V.35/female Winchester 005-0068 25 ft. V.35 Data Cable - male V.35 / female Winchester

V.35 Data Cable - 50 ft.

male V.35/female Winchester 005-0069 50 ft. V.35 Data Cable - male V.35 / female Winchester

V.35 Data Cable - 25 ft.

male V.35/male Winchester 005-0009 25 ft. V.35 Data Cable - male V.35 / male Winchester

V.35 Data Cable - 50 ft.

male V.35/male Winchester 005-0010 50 ft. V.35 Data Cable - male V.35 / male Winchester

T1 Cable - 25 ft. 005-0101 25 ft. RJ48C-to-RJ48C T1 Straight Cable, RJ45 plug on each end

Ethernet Crossover Cable - 2 ft. 005-0102 2 ft. RJ45-to-RJ45 Ethernet Crossover Cable, RJ 45 plug on each end

Ethernet Straight Cable - 6 ft. 005-0103 6 ft. RJ45-to-RJ45 Ethernet Straight Cable, RJ 45 plug on each end

RJ48C-to-DB15P T1 Connector

Adaptor 005-0104 RJ48C-to-DB15P T1 Connector Adaptor  

RJ45-to-DB9P Connector Adaptor 005-0105 RJ45-to-DB9P Connector Adaptor - wired with TXD, RXD and SG

RJ45-to-DB9P Connector Adaptor 005-0106 RJ45-to-DB9P Connector Adaptor - wired with control signals

Included Items

PORTS

• Two RJ-48C T1 ports with integrated CSUs

• Six service card slots for voice & data cards

• Two RJ-21X 50-pin Tip & Ring connectors

• Power input connector

• Female DB-9 RS-232 Management Port

• Single RJ-45 10BaseT port for Ethernet management

• Six-pin alarm connector - major & minor outputs, one input

• Standard three-conductor IEC Equipment AC Receptacle

ACCESSORIES

• Adit 600 user's manual on CD-ROM

• 6 ft. AC power cord

• Adit 600 five blank card face plates

SOFTWARE

• Adit 600 dual T1 TDM Operating System

POWER OPTIONS

• -48 VDC

• Adit 600 battery charger options are available as noted in the above descriptions.